Near Boiler Trim Kits
Performance Data
3450 Combination Boiler Feed Valve and Backflow Preventer:
Max. Inlet Pressure: 150 psi
Min. Delta P Inlet to Outlet: 15 psi
Recommended Setting Range: 10-50 psi +/-3 psi
Factory Setting: 12 psi
Adjustment Capability: 8.5 – 65 psi
Max. Flow Rate (velocity): 25 gpm (8 ft / sec)
Max. Temp.: 210°F
4900 Series® Air Separators:
Max. Working Temp.: 240°F
Min. Working Temp.: 35°F
Max. Working Pressure: 150 psi
Backflow Preventer:
Max. Temp.: 250°F (121°C)
Max. Working Pressure: 175 psi (1206 ksa)
Design Presure Range: 25-250 psi, (172-2413 kps)
Boiler Feed Valves (Reducing Valves):
Max. Fluid Temp.: 212°F (100°C)
Max. Supply Side Pressure: 100 psi (689 kpa)
Setting Range: 10-25 psi (69-172 kpa)
Factory Setting of System Side: 12 psi (83 kpa)
Dual Controls:
Max. Fluid Temp.: 212°F (100°C)
Max. Supply Side Pressure: 100 psi (689 kpa)
Relief Valve Set to Release at 30 psi (207 kpa)
HEX-30 Expansion Tank:
Max. Working Pressure: 100 psig
Max. Working Temp.: 240°F
Tank Pre-Charge: 12 psig
Features
- ASSE listed boiler feed/backflow (Premium)
- ASSE listed backflow (Advanced and Select)
- Select kit combinations suit all preferences
- All fittings & connections included
- Designed for easy installation
- 1” & 1¼” sizes available
- 4½ gallon expansion tank included
- Suitable for use in closed loop systems with water or up to 50% water / glycol solution
Applications
- Hydronic